Objective

To compare the impact of expanded polytetrafluoroethylene (PTFE; Gore-Tex Surgical Membrane; W. L. Gore & Associates, Inc., Flagstaff, AZ) and oxidized regenerated cellulose (Interceed TC7, Johnson & Johnson Medical, Inc., Arlington, TX) on the development of postsurgical adhesions.

Design

A multicenter, nonblinded, randomized clinical trial.

Setting

University medical centers.

Interventions

Each barrier was allocated randomly to the left or right sidewall of every patient.

Patients

Thirty-two women with bilateral pelvic sidewall adhesions undergoing reconstructive surgery and second-look laparoscopy.

Main outcome measures

Adhesion score (on a 0- to 11-point scale), the area of adhesion (cm2), and the likelihood of no adhesions.

Results

The use of both barriers was associated with a lower adhesion score and area of adhesion postoperatively. However, those sidewalls covered with PTFE had a significantly lower adhesion score (0.97 +/- 0.30 versus 4.76 +/- 0.61 points, mean +/- SEM) and area of adhesion (0.95 +/- 0.35 versus 3.25 +/- 0.62 cm2). Overall, more sidewalls covered with PTFE had no adhesions (21 versus 7) and, when adhesions were present on the contralateral sidewall, the number of sidewalls covered with PTFE without adhesions was greater than those covered with oxidized regenerated cellulose (16 versus 2).

Conclusion

Expanded polytetrafluoroethylene was associated with fewer postsurgical adhesions to the pelvic sidewall than oxidized regenerated cellulose.

Topics

gore-tex adhesion prevention, pelvic adhesion barriers comparison, interceed versus ptfe surgery, adhesion prevention laparoscopy, pelvic sidewall adhesion treatment, fertility-sparing adhesion barriers, postoperative adhesion prevention, expanded polytetrafluoroethylene surgery, oxidized cellulose adhesion barrier, second-look laparoscopy adhesions, microsurgery adhesion prevention

Cite this article

Haney, A. F., Hesla, J., Hurst, B. S., Kettel, L. M., Murphy, A. A., Rock, J. A., Rowe, G., & Schlaff, W. D. (1995). Expanded polytetrafluoroethylene (Gore-Tex Surgical Membrane) is superior to oxidized regenerated cellulose (Interceed TC7+) in preventing adhesions. *Fertility and sterility*, *63*(5), 1021-1026.