A simple, safe technique for placement of the veress needle and trocar in laparoscopy

Journal of laparoendoscopic surgery, 2(4), 189-192

DOI 10.1089/lps.1992.2.189 PMID 1388074 Source

Abstract

A simple technique of placing two Kocher clamps on the anterior rectus fascia for the elevation of the anterior abdominal wall during the insertion of the veress needle and the laparoscopic trocar is described in 243 consecutive patients. There were no failed insufflations during this study and no cases of preperitoneal emphysema. The technique is simple to use and adds safety to a basically blind procedure.

Topics

safe trocar placement technique, veress needle insertion laparoscopy, kocher clamp abdominal wall elevation, preventing preperitoneal emphysema, laparoscopic entry technique, blind trocar insertion safety, anterior rectus fascia elevation, minimally invasive surgery safety, hilgers laparoscopy technique, trocar placement complications prevention, safe laparoscopic access method, abdominal wall elevation during insufflation

Cite this article

Hilgers, T. W. (1992). A simple, safe technique for placement of the veress needle and trocar in laparoscopy. *Journal of laparoendoscopic surgery*, *2*(4), 189-192. https://doi.org/10.1089/lps.1992.2.189